菜单
  

    摘要红外焦平面阵列探测器是红外探测系统以及红外热成像器件的关键部件,它被广泛地应用于军事领域和民用领域,具有很大的应用与发展前景。研究测试系统的各个参数性能,尤其是响应特性是非常重要的。63695

    本文的主要工作是在分析红外焦平面阵列探测器测试需求的基础上,通过自行设计的测试系统,我们能够得到各个像元的响应电压数据,通过它们来研究响应特性。

    本文首先从红外焦平面阵列探测器的输出信号采集以及性能参数测试两方面进行分析和研究,然后基于虚拟仪器技术设计和实现了红外焦平面阵列探测器测试系统。主要模块包括红外信号源、红外焦平面阵列探测器、信号调理模块、采集控制模块和数据处理模块。测试系统的硬件设计基于PXI总线结构,软件设计采用LabWindows/CVI模块化的编程方式。

    然后,通过测得的数据来研究测试非制冷红外焦平面阵列探测器光电响应关系及影响因素(主要有面源黑体和环境温度,黑体辐射孔径,焦平面像元面积,黑体出射孔至焦平面像元面垂直距离)和分析不同环境条件(环境温度)对非制冷红外焦平面阵列探测器响应的影响。通过分析指出,选择合适的面源黑体温度和环境温度,我们能够获得好的响应特性,从而获得清晰图像。

    毕业论文关键词     红外焦平面阵列探测器,测试系统,响应度

    毕业设计说明书(论文)外文摘要

    Title  Infrared focal plane array detector response characteristics                      

    Abstract

    Infrared focal plane array detector is an infrared detection system and an infrared thermal imaging device key components, it is widely used in military and civilian fields, has great application and development prospects. The parameters of the test system performance, especially in response characteristics are very important.

    The main work is in the analysis of infrared focal plane array detector test requirements, based on the test system through self-designed, we can get the response of each pixel voltage data, through which to study the response characteristics.

    Firstly, from the infrared focal plane array detector output signal acquisition and performance testing two aspects of analysis and research, and then based on virtual instrument technology design and implementation of an infrared focal plane array detector test system. Main modules including infrared sources, infrared focal plane array detectors, signal conditioning modules, data acquisition and control module and processing module. The hardware design of the test system based on PXI bus architecture, software design using LabWindows / CVI modular programming.

    Then, the measured data to study the test uncooled infrared focal plane array detector photoelectric response relationships and influencing factors (the main area blackbody and ambient temperature blackbody radiation aperture, focal-plane pixel size, bold exit aperture to the focal plane pixel perpendicular distance) and the analysis of different environmental conditions (ambient temperature) for uncooled infrared focal plane array detector response. Through analysis pointed out that choosing the right area blackbody temperature and the ambient temperature, we were able to get a good response characteristics to obtain a clear image.

    Keywords  Infrared focal plane array detectors, test system responsiveness,response

    1  引言 1

    1.1  红外技术概述 1

    1. 2  红外探测技术概述 1

    1. 3  红外探测器概述 2

  1. 上一篇:频率偏移对beacon信号的影响分析
  2. 下一篇:二维经验模式分解在图像融合中的应用研究
  1. MTAIAB多聚焦图像融合算法研究

  2. 人体皮肤红外发射率测试评估技术研究

  3. 近距离多元红外目标方位探测研究

  4. 点运算红外图像增强技术研究

  5. LabWindows虚拟仪器的RLC参数自动测量系统设计

  6. 基于拉普拉斯金字塔分解...

  7. MATLAB红外图像边缘锐化算法研究

  8. 十二层带中心支撑钢结构...

  9. 当代大学生慈善意识研究+文献综述

  10. 河岸冲刷和泥沙淤积的监测国内外研究现状

  11. java+mysql车辆管理系统的设计+源代码

  12. 大众媒体对公共政策制定的影响

  13. 电站锅炉暖风器设计任务书

  14. 中考体育项目与体育教学合理结合的研究

  15. 乳业同业并购式全产业链...

  16. 杂拟谷盗体内共生菌沃尔...

  17. 酸性水汽提装置总汽提塔设计+CAD图纸

  

About

751论文网手机版...

主页:http://www.751com.cn

关闭返回