    ( II ) Allowable pile bearing capacity
    Allowable pile bearing capacity is the sum of the skin resistance and the tip-bearing resistance of a pile. The mechanism of the load transfer from the piles to the soil layer is illustrated as Fig. 2.5(b). The pile bearing capacity depends on several geotechnical and structural factors, such as the ground conditions around the piles, the pile diameter, the pile length, the inclination of the piles and the material of the pile.
     
    The two requirements mentioned hereinbefore control the maximum load capacity per unit plan area of the pile foundation. Therefore, one can increase the total capacity of the pile foundation by: i) increasing the plan area of the pile group so that more piles can be provided, but still satisfying the requirement of minimum pile spacing; ii) increasing the allowable capacity of each pile, the methods of which include ground improvements, longer pile lengths and changes of the pile material.

    However, design constraints exist in selecting one or both of the above options to increase the total capacity of the pile foundation.
    ( I ) Limited increase in plan area
    The maximum plan area is controlled by the spacing between loaded elements, which are columns and walls, and their separation distance from the adjacent structures or lot boundaries. If the pile cap is enlarged, the depth of the cap may need to be increased to resist the increased bending stress, which will increase the cost of the pile foundation, and more importantly, the cost of shoring works for constructing the pile cap.
    ( II ) Limited increase in pile bearing capacity
    There is a practical limit in increasing the capacity of a pile. Very high capacity piles involving Grade 55C steel H-piles and 3m diameter bored piles are already frequently used in Hong Kong. There are difficulties in increasing the pile capacity further..

    As buildings become taller, the subjected building loads become larger and a higher total capacity of the pile foundation is hence demanded. To achieve this, besides the above two options, the pile group efficiency could be enhanced so that the loads can be distributed to and shared by all the piles efficiently, by the rigid cap assumptions in the pile cap design.

    2.3 DIFFERENCES  IN  STRUCTURAL  BEHAVIOUR

    2.3.1 Subjected to vertical loading without bending moment
    In normal circumstances, vertical loads acting on a pile group produce a vertical displacement as well as out-of-plane rotation of the pile cap. For simplicity, the resultant vertical load is assumed in this section to act at the centroid of the pile group such that no bending moment is generated by the subjected resultant vertical load. The torque produced by the lateral load on the supporting building, as well, is not considered in this section. Finite element models of a 6x6 pile group, one with a rigid cap and another with a flexible cap, are constructed by ABAQUS (2002) for analysis as shown in Fig. 2.6, with bending moments in both directions omitted.
     
    A rigid cap, when subjected to a resultant vertical load at the centroid of the pile group, keeps a nearly planar shape by redistributing the load throughout the whole cap. In the case with identical pile lengths, shown in Fig. 2.6, the resulting deformed rigid cap stays horizontal yet at a lowered position as shown in Fig. 2.7(a). The deformation of each pile is the same, resulting in identical pile loads for the whole pile group, as plotted in Fig. 2.8.
    With loss of rigidity, however, a flexible cap bends and twists besides the rigid-body displacement and rotation, when subjected to a resultant vertical load at the centroid of the pile group. It leads to a curved deformed shape as shown in Fig. 2.7(b), with the maximum vertical deflection at the centroid of the pile group where the resultant vertical load acts. The pile loads are not uniform among the piles. Piles located around the centroid support most of the subjected vertical loads while the surrounding piles are only lightly loaded, as shown in Fig. 2.9.
  1. 上一篇:梭罗的自然观与中国生态文献综述和参考文献
  2. 下一篇:柴油喷嘴雾化英文文献和翻译
  1. 钢筋混凝土柱在火灾中的...

  2. 振动台实验和动态响应地...

  3. 钢筋混凝土框架英文文献和中文翻译

  4. 体外预应力钢筋混凝土梁的刚度英文文献

  5. 雷达成像技术对钢筋混凝...

  6. 高层建筑设计与城市空间英文文献和中文翻译

  7. 钢筋混凝土英文文献及中文翻译

  8. 电站锅炉暖风器设计任务书

  9. 杂拟谷盗体内共生菌沃尔...

  10. 河岸冲刷和泥沙淤积的监测国内外研究现状

  11. 当代大学生慈善意识研究+文献综述

  12. 大众媒体对公共政策制定的影响

  13. java+mysql车辆管理系统的设计+源代码

  14. 十二层带中心支撑钢结构...

  15. 中考体育项目与体育教学合理结合的研究

  16. 乳业同业并购式全产业链...

  17. 酸性水汽提装置总汽提塔设计+CAD图纸

  

About

751论文网手机版...

主页:http://www.751com.cn

关闭返回